Operational Modal Analysis and Finite Element Model Updating of the Naillac Tower in Rhodes, Greece


World Heritage Site: Medieval City of Rhodes

Publication Year: 2025

Publication Type: Conference paper

Publication Identifier: WHEFBA7ECDB14

Summary

A study on the Naillac Tower, part of Rhodes' medieval cityrevealed significant discrepancies between assumed and actual material properties of its stone masonry. By combining 3D documentation (using digital cameras, laser scanners, drones, and total stations) with operational modal analysis (OMA), researchers developed a calibrated finite element model that accurately reflects the tower's dynamic behavior. This approach, which integrates ambient vibration testing data, underscores the necessity of OMA-based calibration for vulnerability assessments in historical structures, offering insights critical for sustainable restoration practices.

Citation

Shabani, A., & Karimi, A. H. (2025). Operational Modal Analysis and Finite Element Model Updating of the Naillac Tower in Rhodes, Greece. The 1st International Conference on Net-Zero Built Environment, 1335–1345. https://doi.org/10.1007/978-3-031-69626-8_112

You are here:
World Heritage Explorer > World Heritage Research > Publications > Operational Modal Analysis and Finite Element Model Updating of the Naillac Tower in Rhodes, Greece

This website includes data sources licensed under CC BY-SA 4.0. Additional original content by World Heritage Explorer, also licensed under CC BY-SA 4.0. WHE is not affiliated with UNESCO or the World Heritage Committee. Legal Notice. Privacy Policy.