Summary
Research reveals that roof interventions in the Basilica of San Francesco, Assisi, significantly altered its seismic response during the 1997 Umbria-Marche earthquake. These modifications decreased the structure's fundamental period, redirecting seismic loads toward the façade and transept, likely contributing to the collapse of two Gothic vaults. The study employed a simple analytical model to assess how changes in roof stiffness and mass over centuries influenced the basilica's dynamic behavior during the second shock. Findings suggest that cumulative damage from previous earthquakes and retrofitting interventions may have played a critical role in the 1997 collapse, highlighting the complex interplay between historical modifications and seismic vulnerability.
Citation
Arcidiacono, V., Piermarini, E., Cimellaro, G. P., & Oschendorf, J. (2015). The dynamic behaviour of the roof interventions in the Basilica San Francesco in Assisi. IABSE Conference, Nara 2015: Elegance in Structures, 104, 208–209. https://doi.org/10.2749/222137815815774629